Garedew 2005 Eur Shock Soc: Difference between revisions

From Bioblast
No edit summary
No edit summary
Line 11: Line 11:
}}
}}
{{Labeling
{{Labeling
|area=Respiration, Instruments and methods
|organism=Human
|organism=Human
|model cell lines=Fibroblast
|model cell lines=Fibroblast
|preparations=Intact cells
|preparations=Intact cells
|topics=Uncoupler
|couplingstates=OXPHOS
|couplingstates=OXPHOS
|kinetics=Inhibitor; Uncoupler
|instruments=Oxygraph-2k, TIP2k
|instruments=Oxygraph-2k, TIP2k
|additional=Instrumental and methodological aspects
|additional=Instrumental and methodological aspects
|discipline=Mitochondrial Physiology
|discipline=Mitochondrial Physiology
}}
}}

Revision as of 13:20, 11 August 2013

Publications in the MiPMap
Garedew A, HΓΌtter E, Haffner B, Gradl P, Gradl L, Jansen-DΓΌrr P, Gnaiger E (2005) High-resolution respirometry for the study of mitochondrial function in health and disease. The OROBOROS Oxygraph-2k. Proc 11th Congress Eur Shock Soc, Vienna, Austria (Redl H, ed) Medimond, Bologna: 107-111.

Β» Weblink

Garedew A, Huetter E, Haffner B, Gradl P, Gradl L, Jansen-Duerr P, Gnaiger E (2005) Medimond

Abstract: High-resolution respirometry with mitochondria, cells or biopsies is based on the unique features of the OROBOROS Oxygraph-2k, combining instrumental design, electronics and task-specific DatLab software. Various respiratory states are analyzed with <0.4 million cells or <4 mg biopsy (muscle, liver) per assay. Complex substrate/inhibitor titration protocols are used to quantify functional properties of selected components of the respiratory chain. The electronic titration-injection micropump TIP2k is applied for kinetics as a modular component of the Oxygraph-2k. DatLab 4 provides on-line instrumental background corrections of oxygen flux and on-line data analysis, and tabulated results are available at the end of an experiment. This sets a new standard for biomedical and clinical studies, combining high-resolution with instant diagnostic information.


β€’ O2k-Network Lab: AT_Innsbruck_Gnaiger E, AT_Innsbruck_Jansen-Duerr P, AT Innsbruck MitoCom


Labels: MiParea: Respiration, Instruments and methods"Instruments and methods" is not in the list (Respiration, Instruments;methods, mt-Biogenesis;mt-density, mt-Structure;fission;fusion, mt-Membrane, mtDNA;mt-genetics, nDNA;cell genetics, Genetic knockout;overexpression, Comparative MiP;environmental MiP, Gender, ...) of allowed values for the "MiP area" property. 


Organism: Human 

Preparation: Intact cells 

Regulation: Uncoupler  Coupling state: OXPHOS 

HRR: Oxygraph-2k, TIP2k 

Instrumental and methodological aspects 

Cookies help us deliver our services. By using our services, you agree to our use of cookies.