Harmonized SUIT protocols: Difference between revisions
No edit summary |
No edit summary |
||
Line 1: | Line 1: | ||
{{MitoPedia | {{MitoPedia | ||
|abbr=H-SUIT | |abbr=H-SUIT | ||
|description='''Harmonized [[SUIT protocols]]''' (H-SUIT) are designed to include [[cross-linked respiratory states]]. When performing | |description='''Harmonized [[SUIT protocols]]''' (H-SUIT) are designed to include [[cross-linked respiratory states]]. When performing harmonized SUIT protocols in parallel, measurements of cross-linked respiratory states can be statistically evaluated as replicates across protocols. Additional information is obtained on respiratory coupling and substrate control by including respiratory states that are not common (not cross-linked) across the harmonized protocols. | ||
|info=[[MiPNet21.06 SUIT reference protocol]] | |info=[[MiPNet21.06 SUIT reference protocol]] | ||
}} | }} | ||
Line 12: | Line 12: | ||
}} | }} | ||
{{MitoPedia topics}} | {{MitoPedia topics}} | ||
Contribution by [[Gnaiger E]] 2016-01-24 | Contribution by [[Gnaiger E]] 2016-01-24, edited 2016-03-02 |
Revision as of 10:08, 2 March 2016
Description
Harmonized SUIT protocols (H-SUIT) are designed to include cross-linked respiratory states. When performing harmonized SUIT protocols in parallel, measurements of cross-linked respiratory states can be statistically evaluated as replicates across protocols. Additional information is obtained on respiratory coupling and substrate control by including respiratory states that are not common (not cross-linked) across the harmonized protocols.
Abbreviation: H-SUIT
Reference: MiPNet21.06 SUIT reference protocol
MitoPedia concepts: "MitoFit Quality Control System" is not in the list (MiP concept, Respiratory state, Respiratory control ratio, SUIT concept, SUIT protocol, SUIT A, SUIT B, SUIT C, SUIT state, Recommended, ...) of allowed values for the "MitoPedia concept" property.
MitoFit Quality Control System"MitoFit Quality Control System" is not in the list (Enzyme, Medium, Inhibitor, Substrate and metabolite, Uncoupler, Sample preparation, Permeabilization agent, EAGLE, MitoGlobal Organizations, MitoGlobal Centres, ...) of allowed values for the "MitoPedia topic" property.
MitoPedia O2k and high-resolution respirometry: "SUIT protocol" is not in the list (O2k hardware, DatLab, Oroboros QM, O2k-Open Support, O2k-Respirometry, O2k-FluoRespirometry) of allowed values for the "MitoPedia O2k and high-resolution respirometry" property. SUIT protocol"SUIT protocol" is not in the list (O2k hardware, DatLab, Oroboros QM, O2k-Open Support, O2k-Respirometry, O2k-FluoRespirometry) of allowed values for the "MitoPedia O2k and high-resolution respirometry" property.
Contribution by Gnaiger E 2016-01-24, edited 2016-03-02