OroboPOS-Service Kit

From Bioblast
Jump to: navigation, search

Header ecosystem 2020.jpg

News - Agenda         O2k-Open Support         O2k-Publications         O2k-Workshops and Events         O2k-Network         O2k-Feedback         NextGen-O2k



OroboPOS-Service Kit

O2k-Catalogue

Description OroboPOS-Service_Kit, with O2k-Service Box including all oxygen sensor service accessories for membrane mounting and service of the OroboPOS.
Product ID 20610-03
Type OroboPOS, O2k, O2k-FluoRespirometer, Startup O2k-Respirometer
Link MiPNet22.11, MiPNet19.18B POS-service
Image
ServiceBox G 2.jpg

The OroboPOS-Service Kit consists of

TitleDescriptionProduct idProduct image
O2k-Service BoxO2k-Service Box empty, contains components of the OroboPOS-Service Kit and the O2k-Assembly Kit.26101-03
OroboPOS-Seal TipOroboPOS-Seal Tip, black butyl rubber gasket with 3 mm pore. 4/Pck, for sealing the OroboPOS (sensor head) against the O2k-Chamber. Push the wetted OroboPOS-Seal Tip over the POS-sensor head, with the pore positioned centrally, not covering any peripheral area of the gold cathode. Do not stretch the gasket across the POS-sensor head. One pack (4 seal tips) of this product is a standard component of the OroboPOS-Service Kit.26110-01
POS seal tip.jpg
OroboPOS-MembranesOroboPOS-Membranes, FEP 25 µm; 40/Pck. Two packages of this item are standard components of the OroboPOS-Service Kit.26200-01
POS membranes.jpg
OroboPOS-Electrolyte PowderOroboPOS-Electrolyte Powder, KCl.

This item is a standard component of the OroboPOS-Service Kit.

The powder is dissolved in 10 ml distilled water to yield a 1 M KCl solution.
26300-01
POS Electrolyte powder.jpg
OroboPOS-Mounting ToolOroboPOS-Mounting Tool for application of OroboPOS-Membranes. It consists of two parts, (i) the membrane guide (larger diameter) and (ii) the membrane ring holder with O-ring\Viton\6x1 mm for holding the OroboPOS-Membrane Ring during membrane application. This item is a standard component of the OroboPOS-Service Kit.26400-02
POS mounting tool for membrane application 02.JPG
OroboPOS-Polishing ClothOroboPOS-Polishing Cloth for cathode cleaning. Replace the OroboPOS-Polishing Cloth at intervals. A two-year interval may be considered in cases of intensive use. This item is a standard component of the OroboPOS-Service Kit.26510-01
POS polishing cloth for cathode cleaning.jpg
OroboPOS-Polishing PowderOroboPOS-Polishing Powder for cathode cleaning. This item is a standard component of the OroboPOS-Service Kit.26520-01
POS polishing powder for cathode cleaning.jpg
O2-Zero PowderO2-Zero Powder, dithionite (Na2S2O4), for zero-oxygen calibration of the OroboPOS. This item is a standard component of the OroboPOS-Service Kit.26600-01
O2-Zero Powder.jpg
Forceps for membrane applicationForceps for membrane application: for OroboPOS and ISE membrane application; do not use for tissue preparation. This item is a standard component of the OroboPOS-Service Kit and the O2k-TPP+ ISE-Module.26700-01
Forcep for membrane application.jpg
Pipette\Plastic\1 ml ungradedPipette\Plastic\1 mL ungraded, for filling electrolyte into the reservoir of the OroboPOS. This item is a standard component of the OroboPOS-Service Kit.26800-01
Pipette Plastic 1 ml-ungraded.JPG