Cookies help us deliver our services. By using our services, you agree to our use of cookies. More information

Difference between revisions of "Biochemical threshold effect"

From Bioblast
(Created page with "{{MitoPedia |description=Due to threshold effects, even a large defect diminishing the velocity of an individual enzyme results in only minor changes of pathway flux. |type=MiP }...")
Β 
Β 
(11 intermediate revisions by 2 users not shown)
Line 1: Line 1:
{{MitoPedia
{{MitoPedia
|description=Due to threshold effects, even a large defect diminishing the velocity of an individual enzyme results in only minor changes of pathway flux.
|description=Due to threshold effects, even a large defect diminishing the velocity of an individual enzyme results in only minor changes of pathway flux.
|type=MiP
|info=[[Gnaiger 2020 BEC MitoPathways]]
}}
}}
{{Labeling
[[File:NS-threshold.jpg|400px|thumb|Biochemical threshold plot for convergent NS (CI<small>&</small>II-linked; full line, left) and N (CI-linked) pathway flux based on electron gating (dotted line, right). An enzymatic defect of a single step (CIV) exerts no or little effect on N-pathway and NS-pathway flux (horizontal lines) up to a threshold. Beyond the threshold a linear slope is obtained, which is extrapolated to the apparent excess capacity of the single step. The physiological threshold is overestimated for N-pathway flux, which is restricted by electron gating ([[Gnaiger 2020 BEC MitoPathways]].]]
|discipline=Mitochondrial Physiology
Β 
|topics=Respiration; OXPHOS; ETS Capacity
{{MitoPedia methods
|mitopedia method=Respirometry
}}
}}

Latest revision as of 19:45, 1 January 2021


high-resolution terminology - matching measurements at high-resolution


Biochemical threshold effect

Description

Due to threshold effects, even a large defect diminishing the velocity of an individual enzyme results in only minor changes of pathway flux.


Reference: Gnaiger 2020 BEC MitoPathways

Biochemical threshold plot for convergent NS (CI&II-linked; full line, left) and N (CI-linked) pathway flux based on electron gating (dotted line, right). An enzymatic defect of a single step (CIV) exerts no or little effect on N-pathway and NS-pathway flux (horizontal lines) up to a threshold. Beyond the threshold a linear slope is obtained, which is extrapolated to the apparent excess capacity of the single step. The physiological threshold is overestimated for N-pathway flux, which is restricted by electron gating (Gnaiger 2020 BEC MitoPathways.


MitoPedia methods: Respirometry