Cookies help us deliver our services. By using our services, you agree to our use of cookies. More information

Difference between revisions of "Fasching 2012 Abstract Bioblast"

From Bioblast
Line 5: Line 5:
|year=2012
|year=2012
|event=[[Bioblast 2012]]
|event=[[Bioblast 2012]]
|abstract=
|abstract=[[File:Mario.jpg|right|150px|Fasching Mario]] High-resolution respiromety [1] is extended by MultiSensor techniques allowing the simultaneous measurement of oxygen consumption and one additional parameter (mitochondrial membrane potential, pH, Ca<sup>2+</sup>, or NO concentration [2,3]). Combining optical measurements with high-resolution respirometry further increased the range of analytical opportunities. In particular, fluorometric methods are available for a wide range of analytical parameters of major interest in mitochochondrial physiology: H<sub>2</sub>O<sub>2</sub> production, mitochondrial membrane potential, intracellular pH, Ca<sup>2+</sup>, Mg<sup>2+</sup>, and NADH levels.
 
 
[1] Gnaiger E (2008) Polarographic oxygen sensors, the oxygraph and high-resolution respirometry to assess mitochondrial function. In: Mitochondrial Dysfunction in Drug-Induced Toxicity (Dykens JA, Will Y, eds.) John Wiley: 327-352.
[1] Gnaiger E (2008) Polarographic oxygen sensors, the oxygraph and high-resolution respirometry to assess mitochondrial function. In: Mitochondrial Dysfunction in Drug-Induced Toxicity (Dykens JA, Will Y, eds.) John Wiley: 327-352.



Revision as of 14:13, 12 November 2012

Fasching M (2012) O2k-Fluorimetry - a MitoCom project. Mitochondr Physiol Network 17.12.

Link: MiPNet17.12 Bioblast 2012 - Open Access

Fasching M, Sumbalova Z, Gnaiger E (2012)

Event: Bioblast 2012

Fasching Mario

High-resolution respiromety [1] is extended by MultiSensor techniques allowing the simultaneous measurement of oxygen consumption and one additional parameter (mitochondrial membrane potential, pH, Ca2+, or NO concentration [2,3]). Combining optical measurements with high-resolution respirometry further increased the range of analytical opportunities. In particular, fluorometric methods are available for a wide range of analytical parameters of major interest in mitochochondrial physiology: H2O2 production, mitochondrial membrane potential, intracellular pH, Ca2+, Mg2+, and NADH levels.


[1] Gnaiger E (2008) Polarographic oxygen sensors, the oxygraph and high-resolution respirometry to assess mitochondrial function. In: Mitochondrial Dysfunction in Drug-Induced Toxicity (Dykens JA, Will Y, eds.) John Wiley: 327-352.

[2] Aguirre E, Rodríguez-Juárez F, Bellelli A, Gnaiger E, Cadenas S (2010) Kinetic model of the inhibition of respiration by endogenous nitric oxide in intact cells. Biochim Biophys Acta 1797: 557-565.

[3] Mipnetanalyzer


O2k-Network Lab: AT Innsbruck OROBOROS, AT Innsbruck Gnaiger E


Labels:


Organism: Mouse  Tissue;cell: Neurons; Brain"Neurons; Brain" is not in the list (Heart, Skeletal muscle, Nervous system, Liver, Kidney, Lung;gill, Islet cell;pancreas;thymus, Endothelial;epithelial;mesothelial cell, Blood cells, Fat, ...) of allowed values for the "Tissue and cell" property. 



HRR: Oxygraph-2k, Spectrophotometry"Spectrophotometry" is not in the list (Oxygraph-2k, TIP2k, O2k-Fluorometer, pH, NO, TPP, Ca, O2k-Spectrophotometer, O2k-Manual, O2k-Protocol, ...) of allowed values for the "Instrument and method" property. 




Affiliations and author contributions

Mario Fasching (1), Zuzana Sumbalova (2), Erich Gnaiger (1,3)

(1) Oroboros Instruments GmbH, Innsbruck, Austria

(2) Comenius University, Bratislava, Slovak Republic

(3) Innsbruck Medical University, Austria. – [email protected]


Help