Cookies help us deliver our services. By using our services, you agree to our use of cookies. More information

Difference between revisions of "MiPNet17.03 Shredder vs Fibers"

From Bioblast
Line 16: Line 16:
|articletype=Protocol; Manual, MiPNet-online Publication
|articletype=Protocol; Manual, MiPNet-online Publication
}}
}}
== References ==
* [[Gross_2011_Analyt Biochem|Gross VS, Greenberg HK, Baranov SV, Carlson GM, Stavrovskaya IG, Lazarev AV, Kristal BS (2011) Isolation of functional mitochondria from rat kidney and skeletal muscle without manual homogenization. Analyt Biochem 418: 213-223]].
* Doerrier C, Draxl A, Wiethüchter A, Eigentler A, Gnaiger E (2012) Mitochondrial respiration in permeabilized fibres versus homogenate from mouse myocardium. An application study with the PBI-Shredder. Mitocondr Physol Network 17.03: 1-12.
* Pressure BioSciences Inc. The Shredder SG3 and Shredder PULSE Tubes: Product Specification Sheet: 1-2.
* Pressure BioSciences Inc. The Shredder SG3: User Manual: 1-16.
''Mitochondr Physiol Network – MiPNet Manuals and Protocols''





Revision as of 16:21, 14 May 2012

Publications in the MiPMap
Draxl A, Eigentler A, Gnaiger E. Mitochondrial respiration in permeabilized fibres versus homogenate from mouse myocardium. An application study with the PBI-Shredder. Mitochondr Physiol Network 17.03.

» PBI-Shredder HRR-Set

Doerrier C, Draxl A, Wiethuechter A, Eigentler A, Gnaiger E (2012) Mitochondr Physiol Network

Abstract: In the present study we compared mitochondrial function of permeabilized fibres and homogenate of heart muscle of mice. In addition, respiration of trout heart homogenate preparations were compared with permeabilized fibres, and the PBI-Shredder was successfully tested with preparation of trout liver. Keywords: Tissue homogenate, shredder

O2k-Network Lab: AT_Innsbruck_OROBOROS, AT_Innsbruck_Gnaiger E


Labels:



Preparation: Homogenate 



HRR: Oxygraph-2k, O2k-Manual, Protocol"Protocol" is not in the list (Oxygraph-2k, TIP2k, O2k-Fluorometer, pH, NO, TPP, Ca, O2k-Spectrophotometer, O2k-Manual, O2k-Protocol, ...) of allowed values for the "Instrument and method" property., MiPNet-Publication"MiPNet-Publication" is not in the list (Oxygraph-2k, TIP2k, O2k-Fluorometer, pH, NO, TPP, Ca, O2k-Spectrophotometer, O2k-Manual, O2k-Protocol, ...) of allowed values for the "Instrument and method" property. 

mt-Preparation 



Author contributions and progress

Prepared by Doerrier Velasco C, Draxl A, Eigentler A and Gnaiger E. DC, Wiethüchter A and DA performed the experiments.

  • First on-line version: 2012-05-14.