Difference between revisions of "MiPNet17.03 Shredder vs Fibers"
Line 7: | Line 7: | ||
|abstract=In the present study we compared mitochondrial function of permeabilized fibres and homogenate of heart muscle of mice. In addition, respiration of trout heart homogenate preparations were compared with permeabilized fibres, and the PBI-Shredder was successfully tested with preparation of trout liver. | |abstract=In the present study we compared mitochondrial function of permeabilized fibres and homogenate of heart muscle of mice. In addition, respiration of trout heart homogenate preparations were compared with permeabilized fibres, and the PBI-Shredder was successfully tested with preparation of trout liver. | ||
|keywords=Tissue homogenate, shredder | |keywords=Tissue homogenate, shredder | ||
|mipnetlab=AT_Innsbruck_OROBOROS, AT_Innsbruck_Gnaiger E | |mipnetlab=AT_Innsbruck_OROBOROS, AT_Innsbruck_Gnaiger E, AT Innsbruck MitoCom | ||
|articletype=Protocol; Manual, MiPNet-online Publication | |articletype=Protocol; Manual, MiPNet-online Publication | ||
}} | }} |
Revision as of 14:37, 7 December 2012
Doerrier C, Draxl A, Wiethuechter A, Eigentler A, Gnaiger E. Mitochondrial respiration in permeabilized fibres versus homogenate from mouse myocardium. An application study with the PBI-Shredder. Mitochondr Physiol Network 17.03. |
Doerrier C, Draxl A, Wiethuechter A, Eigentler A, Gnaiger E (
Abstract: In the present study we compared mitochondrial function of permeabilized fibres and homogenate of heart muscle of mice. In addition, respiration of trout heart homogenate preparations were compared with permeabilized fibres, and the PBI-Shredder was successfully tested with preparation of trout liver. β’ Keywords: Tissue homogenate, shredder
β’ O2k-Network Lab: AT_Innsbruck_OROBOROS, AT_Innsbruck_Gnaiger E, AT Innsbruck MitoCom
Labels:
Preparation: Homogenate
Coupling state: LEAK, OXPHOS, ETS"ETS" is not in the list (LEAK, ROUTINE, OXPHOS, ET) of allowed values for the "Coupling states" property.
HRR: Oxygraph-2k, Protocol"Protocol" is not in the list (Oxygraph-2k, TIP2k, O2k-Fluorometer, pH, NO, TPP, Ca, O2k-Spectrophotometer, O2k-Manual, O2k-Protocol, ...) of allowed values for the "Instrument and method" property., MiPNet-Publication"MiPNet-Publication" is not in the list (Oxygraph-2k, TIP2k, O2k-Fluorometer, pH, NO, TPP, Ca, O2k-Spectrophotometer, O2k-Manual, O2k-Protocol, ...) of allowed values for the "Instrument and method" property.
mt-Preparation
- First on-line version: 2012-05-14.