Cookies help us deliver our services. By using our services, you agree to our use of cookies. More information

Difference between revisions of "MiPNet18.05 Amplex-Mouse-heart"

From Bioblast
Line 2: Line 2:
|title=[[Image:O2k-Protocols.jpg|right|80px|link=O2k-Protocols|O2k-Protocols]] O2k-Fluorometry: HRR and H<sub>2</sub>O<sub>2</Sub> production in mouse cardiac tissue homogenate.
|title=[[Image:O2k-Protocols.jpg|right|80px|link=O2k-Protocols|O2k-Protocols]] O2k-Fluorometry: HRR and H<sub>2</sub>O<sub>2</Sub> production in mouse cardiac tissue homogenate.
|info=[[File:PDF.jpg|100px|link=http://wiki.oroboros.at/images/2/2a/MiPNet18.05_Amplex-Mouse-heart.pdf |Bioblast pdf]]
|info=[[File:PDF.jpg|100px|link=http://wiki.oroboros.at/images/2/2a/MiPNet18.05_Amplex-Mouse-heart.pdf |Bioblast pdf]]
|authors=OROBOROS
|authors=Oroboros
|year=2015-06-16
|year=2015-06-16
|journal=Mitochondr Physiol Network
|journal=Mitochondr Physiol Network
|abstract='''Eigentler A, Fontana-Ayoub M, Gnaiger E (2015) O2k-Fluorometry: HRR and H<sub>2</sub>O<sub>2</Sub> production in mouse cardiac tissue homogenate. Mitochondr Physiol Network 18.05(02):1-6.''' »[http://www.bioblast.at/index.php/File:MiPNet18.05_Amplex-Mouse-heart.pdf Versions]
|abstract='''Eigentler A, Fontana-Ayoub M, Gnaiger E (2015) O2k-Fluorometry: HRR and H<sub>2</sub>O<sub>2</Sub> production in mouse cardiac tissue homogenate. Mitochondr Physiol Network 18.05(02):1-6.''' »[http://www.bioblast.at/index.php/File:MiPNet18.05_Amplex-Mouse-heart.pdf Versions]


The [[O2k-Fluorescence LED2-Module]] is an extension of the OROBOROS O2k for combining high-resolution respirometry and fluorometric measurements. We applied the Fluo-Sensor Green for measurement of H<sub>2</sub>O<sub>2</Sub> production with Amplex® Ultrared in mouse heart mitochondria. Experiments are selected to demonstrate the importance of applying ETS-competent substrate states, which are critically evaluated by respiratory performance and considering experimental oxygen levels when measuring mitochondrial H<sub>2</sub>O<sub>2</Sub> production.
The [[O2k-Fluorescence LED2-Module]] is an extension of the Oroboros O2k for combining high-resolution respirometry and fluorometric measurements. We applied the Fluo-Sensor Green for measurement of H<sub>2</sub>O<sub>2</Sub> production with Amplex® Ultrared in mouse heart mitochondria. Experiments are selected to demonstrate the importance of applying ETS-competent substrate states, which are critically evaluated by respiratory performance and considering experimental oxygen levels when measuring mitochondrial H<sub>2</sub>O<sub>2</Sub> production.
:>> Product: [http://www.oroboros.at/?oxygraph OROBOROS O2k], [[OROBOROS O2k-Catalogue | O2k-Catalogue]]
:>> Product: [[Oroboros O2k], [[OROBOROS O2k-Catalogue | O2k-Catalogue]]
:>> [[Permeabilized muscle fibres]]
:>> [[Permeabilized muscle fibres]]
|mipnetlab=AT Innsbruck OROBOROS, AT Innsbruck MitoCom
|mipnetlab=AT Innsbruck Oroboros, AT Innsbruck MitoCom
|link=
|link=
}}
}}

Revision as of 10:23, 17 October 2017

{{Publication

|title=

O2k-Protocols

O2k-Fluorometry: HRR and H2O2 production in mouse cardiac tissue homogenate.

|info=Bioblast pdf |authors=Oroboros |year=2015-06-16 |journal=Mitochondr Physiol Network |abstract=Eigentler A, Fontana-Ayoub M, Gnaiger E (2015) O2k-Fluorometry: HRR and H2O2 production in mouse cardiac tissue homogenate. Mitochondr Physiol Network 18.05(02):1-6. »Versions

The O2k-Fluorescence LED2-Module is an extension of the Oroboros O2k for combining high-resolution respirometry and fluorometric measurements. We applied the Fluo-Sensor Green for measurement of H2O2 production with Amplex® Ultrared in mouse heart mitochondria. Experiments are selected to demonstrate the importance of applying ETS-competent substrate states, which are critically evaluated by respiratory performance and considering experimental oxygen levels when measuring mitochondrial H2O2 production.

>> Product: [[Oroboros O2k], O2k-Catalogue
>> Permeabilized muscle fibres

|mipnetlab=AT Innsbruck Oroboros, AT Innsbruck MitoCom |link= }}

Labels: MiParea: Respiration 


Organism: Mouse  Tissue;cell: Heart  Preparation: Homogenate 

Regulation: Cyt c  Coupling state: LEAK, OXPHOS, ETS"ETS" is not in the list (LEAK, ROUTINE, OXPHOS, ET) of allowed values for the "Coupling states" property.  Pathway: N, S, NS  HRR: Oxygraph-2k, O2k-Fluorometer, O2k-Protocol 

O2k-Demo, O2k-MultiSensor, Mt-Preparation, PBI-Shredder