OroboPOS: Difference between revisions

From Bioblast
No edit summary
No edit summary
Line 2: Line 2:
|description=The '''OroboPOS''' is a polarographic oxygen sensor (POS), with an amperometric mode of operation. The electrochemical POS was introduced by L Clark, with application of a polarization voltage (0.6 to 0.8 V) and measurement of a current (amperometric), which is converted to a voltage.   
|description=The '''OroboPOS''' is a polarographic oxygen sensor (POS), with an amperometric mode of operation. The electrochemical POS was introduced by L Clark, with application of a polarization voltage (0.6 to 0.8 V) and measurement of a current (amperometric), which is converted to a voltage.   


Shipment: OroboPOS are protected in a transparent perspex vial screwed onto a blue POM base, and shipped with the O2k in the [[O2k-Service Box]].
Shipment: OroboPOS are protected in a transparent perspex vial screwed onto a blue POM base, with the [[OroboPOS-Membrane Ring]] arrested on the POS shaft between the POM base and the thicker part of the POS head which holds a [[O-ring\Viton\8x1 mm]].  


[[O2k-Core]]: [[2 OroboPOS]] are included in the O2k-Core unit.
[[O2k-Core]]: [[2 OroboPOS]] are included.
|product id=26000-01
|product id=26000-01
|product type=O2k, OroboPOS
|product type=O2k, OroboPOS
Line 10: Line 10:
|product image=[[File:OroboPOS sensor head.jpg|right|180px|link=]]
|product image=[[File:OroboPOS sensor head.jpg|right|180px|link=]]
}}
}}
* A spare (third) OROBoPOS may be added to the items ordered with the O2k-System.
* A spare (third) OROBoPOS may be added to the items ordered with the O2k-System. OroboPOS are shipped with the O2k in the [[O2k-Service Box]].


* For technical service (troubleshooting) in regard to the POS, see [[POS (technical service)]].
* For technical service (troubleshooting) in regard to the POS, see [[POS (technical service)]].

Revision as of 13:13, 13 February 2012

                



OroboPOS

O2k-Catalogue

Description The OroboPOS is a polarographic oxygen sensor (POS), with an amperometric mode of operation. The electrochemical POS was introduced by L Clark, with application of a polarization voltage (0.6 to 0.8 V) and measurement of a current (amperometric), which is converted to a voltage.

Shipment: OroboPOS are protected in a transparent perspex vial screwed onto a blue POM base, with the OroboPOS-Membrane Ring arrested on the POS shaft between the POM base and the thicker part of the POS head which holds a O-ring\Viton\8x1 mm.

O2k-Core: 2 OroboPOS are included.

Product ID 26000-01
Type O2k, OroboPOS
Link Previous Product ID 26100-24, MiPNet08.04, Gnaiger_1983_POS
Image
OroboPOS sensor head.jpg
  • A spare (third) OROBoPOS may be added to the items ordered with the O2k-System. OroboPOS are shipped with the O2k in the O2k-Service Box.