Difference between revisions of "Stopper\black PEEK\conical Shaft\central Port"

From Bioblast
Line 14: Line 14:
== O2k-Manual ==
== O2k-Manual ==
=== Stoppers and optical measurements ===
=== Stoppers and optical measurements ===
Use only [[Stopper\black PEEK\conical Shaft\central Port|black PEEK stoppers]] in conjunction with optical measurements ([[O2k-Fluo_LED2-Module]]). If necessary, replace the previous [[Stopper\white PVDF\conical Shaft\central Port |white PVDF stoppers]]. The black stoppers can be used for all HRR applications in general. See [[MiPNet12.06]] for calibration of the O2k-chamber volume, which is identical for PEEK and PVDF stoppers.
Use only [[Stopper\black PEEK\conical Shaft\central Port|black PEEK stoppers]] in conjunction with optical measurements ([[O2k-Fluo_LED2-Module]]). If necessary, replace the previous [[Stopper\white PVDF\conical Shaft\central Port |white PVDF stoppers]]. The black stoppers can be used for all HRR applications in general. See [[MiPNet19.18A O2k-start]] for calibration of the [[O2k-Chamber]] volume, which is identical for PEEK and PVDF stoppers.


[[Category:Technical service]]
[[Category:Technical service]]

Revision as of 14:56, 12 July 2017

                



Stopper\black PEEK\conical Shaft\central Port

O2k-Catalogue

Description Stopper\black PEEK\conical Shaft\central Port: with conical shaft and one central capillary (with PTFE, graphite, carbon fiber), Volume-Calibration Ring (A or B) for volume adjustment 1.5 to 3.2 ml; 2 mounted O-rings (O-ring\Viton\12x1 mm). The black PEEK stoppers are required for optical O2k-MultiSensor Modules (O2k-Fluo_LED2-Module).

Two units of this item are standard components of the O2k-Assembly Kit (O2k-Core).

Product ID 24000-01
Type O2k, O2k-Assembly Kit, MultiSensor, O2k-Fluorescence LED2-Module, Stopper
Link O2k-Fluo_LED2-Module
Image
Stopper black PEEK conical Shaft central Port.JPG

Stoppers for O2k-Core

The stoppers are placed in the O2k-Service Box for shipment of the O2k-Core.

O2k-Manual

Stoppers and optical measurements

Use only black PEEK stoppers in conjunction with optical measurements (O2k-Fluo_LED2-Module). If necessary, replace the previous white PVDF stoppers. The black stoppers can be used for all HRR applications in general. See MiPNet19.18A O2k-start for calibration of the O2k-Chamber volume, which is identical for PEEK and PVDF stoppers.