Cookies help us deliver our services. By using our services, you agree to our use of cookies. More information

Difference between revisions of "User talk:Zhang Feiyuan/My sandbox 8"

From Bioblast
Line 1: Line 1:
{{OROBOROS header page name}}
{{Product
{{Publication
|description='''O2k-sV-Chamber''' Β 
|title=[[Image:OROBOROS-solo.png|right|60px|link=OROBOROS INSTRUMENTS]]
|product id=23400-01
'''Innsbruck AT''', 2019 Jul 01-02 Oroboros Distributor Meeting, '''ODM'''.
|product type=O2k, O2k-Module
|authors=Oroboros
|info=[[MiPNet12.10 TIP2k-manual]], [[MiPNet04.05 Titration-Injection]]
|year=2019-07-01
|product image=[[File:TIP2k with 200 mm3 microsyringe.JPG|180px|right]]
|journal=Mitochondr Physiol Network
'''Oroboros Distributor Meeting'''. Innsbruck, Austria; 2019 June.
|mipnetlab=AT_Innsbruck_Oroboros
}}
}}
{{MitoPedia O2k and high-resolution respirometry
|mitopedia O2k and high-resolution respirometry=O2k hardware
}}
== '''TIP2k-Module consists of:''' ==
{{#ask: [[Category:Products]] [[Product type::TIP2k-Module]]
| ?description
| ?product id
| ?product image
|sort=product id
|order=ascending
|mainlabel=Title
}}
== O2k with TIP2k ==
:Β» [[MiPNet12.10_TIP2k-Manual |TIP2k-Manual]]
: The TIP2k is fully supported by the O2k.


The TIP2k is placed at the top of the [[Oroboros O2k]]. It does not need any extra bench space.
::* Align the front legs of the TIP2k with the TIP2k-Spacer Bar on the front of the O2k if you use [[Microsyringe\200 mm3\TIP2k |200 Β΅l syringes]].
::* Align the rear ends of the TIP2k and O2k, if you use [[Microsyringe\500 mm3\TIP2k |500 Β΅l syringes]].


__TOC__
== General information ==
::::
== Feedback ==
== Venue ==
::::Β» to be confirmed
== Programme ==
::::* to be confirmed
== Managers ==
<br/>
<gallery mode=default perrow=4 widths="140px" heights="150px">
File:Erich Gnaiger.jpg|'''[[Gnaiger E |Erich Gnaiger]]''', PhD., Oroboros Instruments, CEO
File:Gnaiger Andrea.jpg|'''[[Gnaiger A |Andrea Gnaiger]]''', Mag.a, Oroboros Instruments - Chief financial officer
File:KranewitterS.JPG|'''[[Kranewitter S |Sabine Kranewitter]]''', MSc., Oroboros Instruments - Chief sales officer
File:ZhangF.jpg|'''[[Zhang F|Feiyuan Zhang]]''', Oroboros Instruments - Chief marketing officer
|-
</gallery>
== Participants ==
{| class="wikitable"
|-
!
! Participant
! Company
! Status
|-
| [[File:Chai Meijian.jpg|70px|Participant]]
| [[Chai Meijian]]
| '''[[CN Shanghai Zenda]]''' -Β  Zenda LLC , Shanghai (CN)
| Preregistered
|-
|}
== Impressions of the ODM01 ==
== Contact ==
:::: '''Oroboros Instruments'''
:::: High-Resolution FluoRespirometry
:::: SchΓΆpfstrasse 18
:::: A-6020 Innsbruck, Austria
:::: Tel: +43 512 566796
:::: Fax: +43 512 566796 20
:::: '''Mitochondria and Cell Research'''




== TIP2k-Syringes ==
* For larger volumes, the [[Microsyringe\500 mm3\TIP2k |500 Β΅l syringes]] are available.
:Β» SOP: [[MiPNet19.14 SOP Hamilton microsyringes |Handling microsyringes]]
* Rinse the outside with water immediately after use.
* Wash 3 x with last used solvent, rinse with EtOH.
* Storage: ethanol (short), dry (longtime).
* Rinse with pure solvent before use.


* Technical support: [[TIP2k syringe blocked]]




Β 
== List of O2k-Publications: TIP2k ==
[[Image:MitoGlobal.jpg|right|80px|link=MitoGlobal|MitoGlobal]]
* [[O2k-Publications: TIP2k]]
O2k-Workshops are listed as [[MitoGlobal Events]].
{{Labeling
|additional=ORO, Next, 2019, MitoGlobal
}}

Revision as of 15:28, 7 June 2019

                



User talk:Zhang Feiyuan/My sandbox 8

O2k-Catalogue

Description O2k-sV-Chamber
Product ID 23400-01
Type O2k, O2k-Module
Link MiPNet12.10 TIP2k-manual, MiPNet04.05 Titration-Injection
Image
TIP2k with 200 mm3 microsyringe.JPG


MitoPedia O2k and high-resolution respirometry: O2k hardware 

TIP2k-Module consists of:

O2k with TIP2k

Β» TIP2k-Manual
The TIP2k is fully supported by the O2k.

The TIP2k is placed at the top of the Oroboros O2k. It does not need any extra bench space.

  • Align the front legs of the TIP2k with the TIP2k-Spacer Bar on the front of the O2k if you use 200 Β΅l syringes.
  • Align the rear ends of the TIP2k and O2k, if you use 500 Β΅l syringes.


TIP2k-Syringes

Β» SOP: Handling microsyringes
  • Rinse the outside with water immediately after use.
  • Wash 3 x with last used solvent, rinse with EtOH.
  • Storage: ethanol (short), dry (longtime).
  • Rinse with pure solvent before use.


List of O2k-Publications: TIP2k