{{ | {{Technical support}} | ||
|description='''Filter set Saf''': Set of filters for the (qualitative) determination of mitochondrial membrane potential withΒ [[Safranin]]. These filters should be used together with [[Fluorescence-Sensor Blue]] or [[Smart Fluo-Sensor Blue]]. The filter set consists of 6 LED filters (round) and 6 photodiode filters (rectangular). | __TOC__ | ||
{{MitoPedia without banner | |||
|abbr= | |||
|description=[[Image:Filter_Set_Saf.JPG|180px|right]]'''Filter set Saf''': Set of filters for the (qualitative) determination of mitochondrial membrane potential withΒ [[Safranin]]. These filters should be used together with [[Fluorescence-Sensor Blue]] or [[Smart Fluo-Sensor Blue]]. The filter set consists of 6 LED filters (round) and 6 photodiode filters (rectangular). Β | |||
|info=[[O2k-Fluorescence LED2-Module]] | |||
}} | |||
== Technical support == Β | |||
[[File:Saf excitation scan 1mA.png|360px]] | |||
:::: '''Excitation''' spectrum obtained with the Fluorescence-Sensor Blue at 1mA current supply and equipped with the Filter Set Saf. | |||
Β | |||
:::: The spectra of '''excitation''' (LED filter: R357) and '''emission''' (photodiode filter: R19) can be found on the webpage of our supplier, ROSCO: https://emea.rosco.com/de/node/1706 (please select the filter numbers to download the specific data sheets). | |||
Β | |||
=== Changing Filters:Β === | |||
:::: [[Filter-Cap]] | |||
{{MitoPedia O2k and high-resolution respirometry | |||
|mitopedia O2k and high-resolution respirometry=O2k hardware, O2k-Open Support, O2k-Respirometry, O2k-FluoRespirometry | |||
}} | }} | ||
Revision as of 16:30, 2 November 2020
Filter Set Saf |
MitoPedia O2k and high-resolution respirometry:
O2k-Open Support
Description
Filter set Saf: Set of filters for the (qualitative) determination of mitochondrial membrane potential with Safranin. These filters should be used together with Fluorescence-Sensor Blue or Smart Fluo-Sensor Blue. The filter set consists of 6 LED filters (round) and 6 photodiode filters (rectangular).
Reference: O2k-Fluorescence LED2-Module
Technical support
- Excitation spectrum obtained with the Fluorescence-Sensor Blue at 1mA current supply and equipped with the Filter Set Saf.
- The spectra of excitation (LED filter: R357) and emission (photodiode filter: R19) can be found on the webpage of our supplier, ROSCO: https://emea.rosco.com/de/node/1706 (please select the filter numbers to download the specific data sheets).
Changing Filters:
MitoPedia O2k and high-resolution respirometry: O2k hardware, O2k-Open Support, O2k-Respirometry, O2k-FluoRespirometry