|abbr=FEP-membranes | |||
|info= | |description=[[Image:POS membranes.jpg|right|180px]]'''[[OroboPOS|POS]]-Membranes''', FEP 25 ยตm; 40/Pck.ย ย | ||
ย | |||
|info=[https://www.oroboros.at/index.php/product/orobopos-membranes/ '''Product details and purchase information'''] | |||
}} | }} | ||
== Storage of POS-Membranes == | |||
:::* The POS-Membranes are stored in the boxes containing originally 40 membranes per package. Each transparent FEP membrane (TEFLON<sup>ยฎ</sup> FEP) is sandwiched between two white circular paper covers, which prevent the FEP membranes from sticking together. A FEP membrane can be used only once and must not be placed back into the membrane box after use. Close the membrane box carefully after removing a membrane, and avoid any external contamination of the unused FEP membranes stored in the box. Under these conditions, the storage time of FEP membranes is practically unlimited without expiration date. | |||
== Additional Resources == | |||
::: ยป[[MiPNet08.04]] | |||
{{MitoPedia O2k and high-resolution respirometry | |||
|mitopedia O2k and high-resolution respirometry=O2k hardware, O2k-Open Support, O2k-Respirometry, O2k-FluoRespirometry}} |
Latest revision as of 11:37, 25 July 2023
POS-Membranes |
MitoPedia O2k and high-resolution respirometry:
O2k-Open Support
Description
POS-Membranes, FEP 25 ยตm; 40/Pck.
Abbreviation: FEP-membranes
Reference: Product details and purchase information
Storage of POS-Membranes
- The POS-Membranes are stored in the boxes containing originally 40 membranes per package. Each transparent FEP membrane (TEFLONยฎ FEP) is sandwiched between two white circular paper covers, which prevent the FEP membranes from sticking together. A FEP membrane can be used only once and must not be placed back into the membrane box after use. Close the membrane box carefully after removing a membrane, and avoid any external contamination of the unused FEP membranes stored in the box. Under these conditions, the storage time of FEP membranes is practically unlimited without expiration date.