Syringe\60 mL\Gas-Injection: Difference between revisions
From Bioblast
No edit summary |
No edit summary |
||
(19 intermediate revisions by 11 users not shown) | |||
Line 1: | Line 1: | ||
{{ | {{Technical support}} | ||
|description='''Syringe\60 | __TOC__ | ||
{{MitoPedia without banner | |||
|abbr= | |||
|description=[[Image:Gas injection syringe.jpg|right|180px]]'''Syringe\60 mL\Gas-Injection''', 60 mL, with spacer and stainless steel needle, flat tip, for gas injection into the [[O2k-chamber]]. | |||
[ | |info=[https://www.oroboros.at/index.php/product/syringe60-mlgas-injection/ '''Product details and purchase information'''] | ||
}} | }} | ||
== Technical support == | |||
:::: When using one or two O2k instruments, a [[Syringe\10 mL\Gas-Injection |10 mL Gas-Injection Syringe]] is fully sufficient. The 10 mL syringe replaces the 60 mL syringe as a standard accessory of the O2k. Injection of a volume of 1 mL of oxygen or 8 mL of nitrogen gas into the gas phase is enough to change the oxygen concentration in the aqueous phase for reoxygenations (O<sub>2</sub>) or for achieving hypoxia (H<sub>2</sub>; or nitrogen or argon). There is a tendency to inject unnecessarily larger volumes with the 60 mL Gas-Injection Syringe. The smaller syringe, therefore, is more practical. The stainless steel needle with a spacer can be easily fitted to the 60 mL or 10 mL Gas-Injection Syringe. | |||
{{MitoPedia O2k and high-resolution respirometry | |||
|mitopedia O2k and high-resolution respirometry=O2k hardware, O2k-Open Support, O2k-Respirometry, O2k-FluoRespirometry}} |
Latest revision as of 16:16, 27 April 2023
Syringe\60 mL\Gas-Injection |
MitoPedia O2k and high-resolution respirometry:
O2k-Open Support
Description
Syringe\60 mL\Gas-Injection, 60 mL, with spacer and stainless steel needle, flat tip, for gas injection into the O2k-chamber.
Reference: Product details and purchase information
Technical support
- When using one or two O2k instruments, a 10 mL Gas-Injection Syringe is fully sufficient. The 10 mL syringe replaces the 60 mL syringe as a standard accessory of the O2k. Injection of a volume of 1 mL of oxygen or 8 mL of nitrogen gas into the gas phase is enough to change the oxygen concentration in the aqueous phase for reoxygenations (O2) or for achieving hypoxia (H2; or nitrogen or argon). There is a tendency to inject unnecessarily larger volumes with the 60 mL Gas-Injection Syringe. The smaller syringe, therefore, is more practical. The stainless steel needle with a spacer can be easily fitted to the 60 mL or 10 mL Gas-Injection Syringe.
MitoPedia O2k and high-resolution respirometry: O2k hardware, O2k-Open Support, O2k-Respirometry, O2k-FluoRespirometry